12 volt water pumps, baldor electric motor, best water softners, deep well water pumps, drinking water filter, electric motors, heat pumps, jet pump, little giant pump, little giant pump company, little giant pumps, myers pumps, pressure tank, pressure tanks, pumps, reverse osmosis, reverse osmosis systems, reverse osmosis water filter, reverse osmosis water systems, sewage pumps, submersible pump, submersible pumps, submersible water pumps, sump pump, sump pumps, us motors, vertical turbine pump, water pump, water pumps, water pumps, water softener, water softeners, water softner, water softner brands, water softners, water well pumps, water wells and pumps, well water pressure tanks, whole house water filter, whole house water filters
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Myers HC & HCM Jet Pumps Technical Information
|
HC50
Shallow Well Selection Table
|
|
Pump
Catalog
Number
|
Motor
HP
|
Jet Package
Cat. No.
|
5 foot Suction Lift
|
15 foot Suction Lift
|
25 foot Suction Lift
|
|
Discharge Pressure,
Pounds
|
Discharge Pressure,
Pounds
|
Discharge Pressure,
Pounds
|
|
20
|
30
|
40
|
50
|
60
|
20
|
30
|
40
|
50
|
60
|
20
|
30
|
40
|
50
|
60
|
|
Capacity in U.S.
Gallons Per Hour
|
|
HC50
|
1/2
|
SW50
|
810
|
780
|
690
|
600
|
400
|
600
|
600
|
560
|
480
|
280
|
330
|
330
|
330
|
300
|
120
|
|
HC50
Deep Well Selection Table
|
|
Pump
Catalog
Number
|
Motor
HP
|
Max. Amps
115/230V
|
Average Regulator
Setting
|
Jet Package Cat. No.
|
Vertical Distance in
Feet from Pump to Low Water Level
|
|
Twin Type
|
Packer
|
30
|
40
|
50
|
60
|
70
|
80
|
90
|
100
|
110
|
|
4" Min. Well
|
2" Well
|
Capacity in U.S.
Gallons Per Hour
|
|
Cast Iron
|
Bronze
|
|
HC50
|
1/2
|
10.6/5.3
|
22 PSI
|
DW50-I
|
DW50
|
P50
|
720
|
660
|
590
|
500
|
390
|
270
|
140
|
-
|
-
|
|
Pump Cat. No.
|
Discharge
|
Pressure Switch
Setting
|
Packer Type Inner
Pipe Size for 2" Well
|
Twin Type Drop Pipe
Size
|
Foot Valve Size -
Twin Type Only
|
Motor Capacitor Type
Built-in Overload Protection
|
|
HC50
|
3/4"
|
20 - 40
|
1"
|
1-1/4" x 1"
|
1-1/4"
|
115/230 volt
|
|
HCM
Shallow Well Selection Table
|
|
Pump
Catalog
Number
|
Motor
HP
|
Jet Package
Cat. No.
|
5 foot Suction Lift
|
15 foot Suction Lift
|
25 foot Suction Lift
|
|
Discharge Pressure,
Pounds
|
Discharge Pressure,
Pounds
|
Discharge Pressure,
Pounds
|
|
30
|
40
|
50
|
60
|
70
|
80
|
30
|
40
|
50
|
60
|
70
|
80
|
30
|
40
|
50
|
60
|
70
|
80
|
|
Capacity in U.S.
Gallons Per Hour
|
|
HCM50
|
1/2
|
SW50
|
630
|
600
|
570
|
540
|
240
|
-
|
480
|
480
|
450
|
420
|
210
|
-
|
390
|
390
|
330
|
330
|
120
|
-
|
|
HCM100
|
1
|
SW100
|
1140
|
1140
|
990
|
960
|
780
|
600
|
780
|
780
|
780
|
720
|
600
|
480
|
480
|
480
|
480
|
480
|
420
|
390
|
|
HCM150
|
1-1/2
|
SW150
|
1350
|
1350
|
1350
|
1200
|
1020
|
780
|
1020
|
1020
|
990
|
960
|
840
|
660
|
560
|
560
|
560
|
560
|
530
|
500
|
|
HCM
Deep Well Selection Table
|
|
Pump
Catalog
Number
|
Motor
HP
|
Max. Amps
115/230V
|
Average Regulator
Setting
|
Jet Package Cat. No.
|
Vertical Distance in
Feet from Pump to Low Water Level
|
|
Twin Type
|
Packer
|
30
|
40
|
50
|
60
|
70
|
80
|
90
|
100
|
110
|
120
|
130
|
140
|
150
|
|
4" Min. Well
|
2" Well
|
Capacity in U.S.
Gallons Per Hour
|
|
Cast Iron
|
Bronze
|
|
HCM50
|
1/2
|
10.6/5.3
|
22 PSI
|
DW50-I
|
DW50
|
P50
|
690
|
570
|
480
|
390
|
330
|
240
|
180
|
120
|
60
|
-
|
-
|
-
|
-
|
|
HCM100
|
1
|
17.0/8.5
|
34 PSI
|
DW100-I
|
DW100
|
P100
|
900
|
800
|
720
|
640
|
560
|
480
|
400
|
320
|
240
|
160
|
80
|
-
|
-
|
|
HCM150
|
1-1/2
|
19.8/9.9
|
40 PSI
|
DW150-I
|
DW150
|
P150
|
1050
|
960
|
870
|
770
|
670
|
570
|
480
|
420
|
360
|
300
|
240
|
180
|
120
|
|
Pump Cat. No.
|
Discharge
|
Pressure Switch
Setting
|
Packer Type Inner
Pipe Size for 2" Well
|
Twin Type Drop Pipe
Size
|
Foot Valve Size -
Twin Type Only
|
Motor Capacitor Type
Built-in Overload Protection
|
|
HCM50
|
3/4"
|
30 - 50
|
1"
|
1-1/4" x 1"
|
1-1/4"
|
115/230 volt
|
|
HCM100
|
1"
|
40 - 60
|
1"
|
1-1/4" x
1-1/4"
|
1-1/4"
|
115/230 volt
|
|
HCM150
|
1"
|
40 - 60
|
1"
|
1-1/4" x
1-1/4"
|
1-1/4"
|
115/230 volt
|
|
 |
 |